Research infrastructure

 

CERNESIM EQUIPMENTS

FACULTY OF CHEMISTRY

LABORATORY OF PHYSICO-CHEMICAL ANALYSIS

1. High resolution atomic absorption spectrophotometer with continuous source ContrAA700 system, ANALYTIC JENA

Contact: Associate Professor, Ph.D., Romeo-Iulian Olariu, e-mail oromeo@uaic.ro, tel. 02320201354

Features: ContrAA700 spectrometer is able to perform simultaneous determination of heavy metals (multi and single element) by atomic absorption process from both liquid and solid samples. The spectrometer is fully automated and is equipped with a system of analysis of samples using flame atomization of acetylene – air/N2O, graphite furnace, hydride generator and a direct analysis system for solid samples. Spectrometer is changing automatic from flame to graphite furnace by software. Spectrometer allows working in a spectral range between 185 and 900 nm. The spectrometer has a single radiation source (Xenon lamp) which enables simultaneous multi-spectral analysis.

2. Analyzer multi N / C ® 3100 series, ANALYTIC JENA

Contact: Associate Professor, Ph.D., e-mail carsene@uaic.ro, tel. 02320201354

Features: Analyser multi N/C® 3100 series is able to determine the content of total nitrogen, total carbon, total inorganic carbon, and total organic carbon, volatile and non-volatile organic carbon in liquid and solid samples (soils). The analyzer has two detectors, one for carbon infrared type and one chemiluminescence type (CLD) for determination of total nitrogen. The analyzer is equipped with a module for analysis of solid samples (soil, sludge).

3. VCD-FTIR spectrometer, BIOTOOLS

Contact: Associate Professor, Ph.D., Romeo-Iulian Olariu, e-mail oromeo@uaic.ro, tel. 02320201354

Features: VCD-FTIR spectrometer is for analysis of natural chiral conformation for different samples (proteins, nucleic acids) and synthetic (pharmaceutical products). Spectral data obtained can then be compared with the results of ab initio calculations to determine the absolute configurations for newly synthesized molecules. Also the spectrometer allows the determination of enantiomeric purity for molecules whose absolute configuration is already known.

4. PTR-TOF-MS spectrometer, KORE

Contact: Associate Professor, Ph.D., Cecilia Arsene, e-mail carsene@uaic.ro, tel. 02320201354

Features: PTR-TOF-MS spectrometer is able to perform real-time, qualitative and quantitative analysis of volatile organic compounds from the air without sample preparation and without using a carrier gas. PTR-TOF-MS spectrometer is based on “soft” chemical ionization (with minimal or no fragmentation of the molecule) method called “proton transfer reaction” (PTR) combined with time-of-flight mass spectrometry (ToF-MS). The spectrometer has a sensitivity of about 200 cps/ppbv for benzene and about 300 cps/ppbv for trichlorobenzene. Mass spectrometer has a resolution of about 2000 m / Δm (FWHM) and is capable to detect compounds with mass in the range 1 – 50 000 amu.

5. Scanning electron microscope (SEM), Quanta 250

Contact: Associate Professor, Ph.D., Cecilia Arsene, e-mail carsene@uaic.ro, tel. 02320201354

Features: Due to the high working pressures than the sample chamber can start (from 6×10-4 Pa up to 2600 Pa), Quanta 250 SEM microscope is the best solution for image analysis and chemical composition of conductive and non-conductive samples, emulsions containing nanoparticles and wet biological samples without previous preparation and to study them in situ evidence of the change in hydration and dehydration processes.

6. Single crystal X-ray diffractometer with dual source, SUPERNOVA250

Contact: Associate Professor, Ph.D., Romeo-Iulian Olariu, e-mail oromeo@uaic.ro, tel. 02320201354

Features: Single crystal X-ray diffractometer with dual source is designed to collect, resolve and determine chemical structures for inorganic and organic samples, organometallic compounds and macromolecules as well. X-ray diffractometer is able to work with two sources (Cu and Mo).

7. LC-MS – Liquid chromatograph with mass spectrometer detector, AGILENT TECHNOLOGIES

Contact: Associate Professor, Ph.D., Cecilia Arsene, e-mail carsene@uaic.ro, tel. 02320201354

Features: LC-MS system is modular consisting of a quaternary pump G1311B model, an unit G1316A model column thermostat, an manual injector G1328C model, an autosampler G 1329B model and an mass spectrometer detector type G6224A model Accurate flight time Agilent TOF-Mass.

8. LC-DAD-FL – Liquid chromatography with both diode array and fluorescence detectors, AGILENT TECHNOLOGIES

Contact: Associate Professor, Ph.D., Cecilia Arsene, e-mail carsene@uaic.ro, tel. 02320201354

Features: It is an modular System consisting of a binary pump G4220A model, column thermostating compartment model G1316C, G1328C model manual injector, autosampler model G4226A detector UV-VIS diode array detector model G4212A and fluorescence.

9. LC-ICP-MS – Liquid chromatography coupled with and inductively coupled plasma mass spectrometer, AGILENT TECHNOLOGIES

Contact: Associate Professor, Ph.D., Cecilia Arsene, e-mail carsene@uaic.ro, tel. 02320201354

Features: The LC-ICP-MS tandem operating system is suitable for the speciation analysis of trace elements (e.g. arsenic from water). It consists of an ICP-MS Agilent 7700 Series model with sensitivity (in cm/s/mg/L) of about 50 for 7Li, 80 for 89Y and 160 for the 205TI. Sample introduction system in ICP-MS is composed of quartz concentric nebulizer G 1820-65138model. RF plasma generator is solid state type with the possibility of adjusting the plasma impedance. Collision cell ensures their removal after interference by kinetic energy discrimination, eliminating the highly reactive gases. ICP-MS system is equipped with a G3286A autosampler ASX -520 models. Liquid chromatograph is composed of a quaternary pump Agilent 1260 Infinity model and a manual injector Agilent 1260 Infinity G 1328C model.

10. SPECTROFLUORIMETER, MODEL FLS-920S, EDINBURGH INTRUMENTS

Contact: Associate Professor, Ph.D., Romeo-Iulian Olariu, e-mail oromeo@uaic.ro, tel. 02320201354

Features: FLS-920s spectrofluorimeter is a modular type is suitable for steady state fluorescence measurements (steady-state) or/and for purchase excitation and emission spectra in the UV-VIS region. It is equipped with a continuous source of radiation, 450W Xenon lamp (no ozone production).

11. HR-ToF-AMS spectrometer of chemical analysis aerosols, Aerodyne Research, AERODYNE

Contact: Associate Professor, Ph.D., Cecilia Arsene, e-mail carsene@uaic.ro, tel. 02320201354

Features: HR-ToF-AMS spectrometer is able to determine the distribution of aerosol load from ambient air, to characterize the emissions from combustion sources and to analyze the chemical composition depending on the particles size of aerosols. Aerosol particles are collected in a vacuum where aerodynamic particles are concentrated in a narrow beam (diameter approx. 1 mm). HR-ToF-AMS spectrometer analysis is performed in real time for inorganic (nitrate, sulphate, ammonium) and organic substances in the rage of 40 nm – 1 microm particle size, 0-1000 amu with a resolution of about 5000 The spectrometer has a sensitivity in the range from 0.002 to 0.05 microg/m3/minute. Sampling of ambient aerosols is directly and is not required filters or chemical analysis off-line.

12. UV-VIS spectrophotometer SPECORD 210 Plus, ANALYTIC JENA

Contact: Associate Professor, Ph.D., Romeo-Iulian Olariu, e-mail oromeo@uaic.ro, tel. 02320201354

Features: SPECORD 210 Plus UV-VIS spectrophotometer is intended for spectrophotometric analysis of absorbance, transmittance, reflectance and energy for liquid and solid samples in controlled temperature conditions. The spectrometer is equipped with the following accessories: a device for solid samples to measure transmittance, a device for supporting films or plates samples, an accessory for measuring diffuse transmittance and reflectance equipped with integrating sphere, able to work in wavelength range of 200-1100 nm with an inner diameter of 75 mm, a device for powders analysis, an automatic suction fluid samples for measurements without changing the sample cuvette, a Pettier thermostatic device, a fibber optic probe with adapter support able to work in wavelength range of 240 to 1100 nm.

13. 500 MHz NMR Spectrometer, BRUKER

Contact: Professor Ph.D., Ionel Mangalagiu, e-mail ionelm@uaic.ro, tel., 02320201343

Features: NMR spectrometer is intended for advanced research and routine quality control of soluble organic compounds, natural compounds or complex metabolites mixtures (e.g. fluids or food). It is equipped with an active shielded superconducting magnet with a magnetic field of 11.7 Tesla and with an inner opening of 54 mm. The system has two equivalent and interchangeable frequency channels for generating broadband frequencies in the range of 18-540 MHz. NMR spectrometer is equipped with a linear amplifier with a minimum pulse power of 50 W from 1H to 19F.

FACULTY OF BIOLOGY

LABORATORY OF ENVIRONMENTAL BIOMONITORING AND REMEDIATION

(Coordinator: Associate Professor, Ph.D., Naela COSTICĂ; cnaela@uaic.ro; 0232201511)

No. Existing equipment Equipment description Location People in charge with the equipment e- mail, telephone
1 Tecnai transmission electron microscope G2 BioTWIN Spirit Maximum acceleration voltage of 120 kV, adjustable in steps of 20 V.

Fluorescent screen magnification in a wider domain of x 20 – x 340 000.

Line resolution better than 0,35 nm.

217 Conf.dr. Lacramioara Ivanescu

Conf.dr. Naela Costică

ivanescu67@yahoo.com

tel: 0729949234

cnaela@uaic.ro

0232201511

2   Shaker for microtitru (I) Shaker with vibration, 6 micro plates, introduction to the Incubator

-          vibrating continue up to 1350 adjustable rpm;

-          shaking platforms with loading capacity of up to 2 kg;

-          clamps for a wide variety of dishes, even for tubes;

-          analog control of vibration frequency

-          timer that allows  operation up to 120 minutes with acoustic signal

462 Lecturer dr. Marius Ştefan stefanm@uaic.ro

tel: 0740077927

3 Leica RM2245 semi-motorized microtome Trimming section thickness 1-600 μm.

Section thickness setting:

1-10 μm in 1-μm increments

10-20 μm in 2-μm increments

20-50 μm in 5-μm increments

50-100 μm in 10-μm increments

100-600 μm in 50-μm increments

453 Conf.dr. Naela Costică cnaela@uaic.ro

0232201511

4 System for the determination of photosynthesis and respiration in gaseous phase System for determination of photosynthesis and respiration in gaseous phase

The system offers the possibility of advanced studies of the phenomena of photosynthesis and respiration of leaf discs.

455 drd. Adrian Bălănici;

drd. Toma Stoleru

adrian.balanici@uaic.ro

tel: 0726210293;

tomi.stoleru@gmail.com

tel: 0743828472

5 System for the determination of photosynthesis and respiration in liquid phase Sophisticated System of liquid phase of photosynthesis research and using large volumes of liquid samples (up to bottle spray) automatic illumination of a red LED (660nm). 455 drd. Adrian Bălănici;

drd. Toma Stoleru

adrian.balanici@uaic.ro

tel: 0726210293;

tomi.stoleru@gmail.com

tel: 0743828472

6 Unit for mineralization (digestion) for the determination of total nitrogen and protein The system is used for liquid or solid samples mineralization in accordance with GLP-Good Laboratory Practices. 457 Lecturer dr. Marius Mihasan;

dr. Marius Nicuşor Grigore

marius.mihasan@uaic.ro

tel:0751894685

mariusgrigorepsyche@yahoo.com

tel: 0766307718

7 Unit for neutralization of the toxic fumes System for neutralising toxic vapour, corrosive, arising from the process of mineralization 457 Lecturer dr. Marius Mihasan;

dr. Marius Nicuşor Grigore

marius.mihasan@uaic.ro

tel:0751894685

mariusgrigorepsyche@yahoo.com

tel: 0766307718

8 Distillation unit Systems of distillation with steam to drive break-up solutions, as well as other evidence, straight from the tubes of the break-up of 250 ml (ø 42) and 100 ml (ø 26) . 457 Lecturer dr. Marius Mihasan;

dr. Marius Nicuşor Grigore

marius.mihasan@uaic.ro

tel:0751894685

mariusgrigorepsyche@yahoo.com

tel: 0766307718

9 Incubator with embedded systems and software for image data processing LEMNATEC Camera:

Frame rate 3.75 fps, 7.5 fps

pixels H:4.65μm V:4.65 μm

Environmental conditions inside

Operating temperature -5°C … 45°C

Storage temperature -20°C … 60°C

Computer integrated.

455 Conf.dr. Naela Costică cnaela@uaic.ro

0232201511

10 Growing chamber for plants This climatic chamber is the most practical solution for plant cultivation “in-vitro” and culture tests. 455 Prof. dr. Maria Magdalena Zamfirache magda@uaic.ro; magda_zamfirache@yahoo.com

tel: 0741271579

11 Lamp UV Bactericidal tube; reflector for concentration of UV radiation; device orientation; power supply for tube UV; power supply: 20V/50 Hz. Power – 15 W; size: 473 × 169 × 93 mm 462 Lecturer dr. Marius Ştefan stefanm@uaic.ro

tel: 0740077927

12 Mechanical Shaker with mutual movement 2-30 movements per minute; amplitude agitation: 20 min; timer: up to 60 min. or operation under continuous; dimensions: 380 ÷ 510 λ 140 mm, weight most of the evidence placed on the turntable: 8 kg; putere: 220 V / 50 Hz. 455 Lecturer dr. Marius Ştefan stefanm@uaic.ro

tel: 0740077927

13 Leica S6 stereomicroscope

with fiber optic illuminator.

Optical data: 6.3:1; Zoom range 15.75x-100x; 25x oculars with 9.5 mm object field; Measurement reticule 5mm/0.5mm; 20W fiber optic illuminator with 500mm  dual branch light gide. 362 Lector dr. Fusu Lucian

Lector dr. Ovidiu Popovici

lucfusu@yahoo.com

tel: 0740751967

ovidiu.alin@email.ro

tel: 0740703969

14 Research microscope Leica DM750 4x, 10x, 40x, 100X objectives; 100X planapochromatic oil immersion objective with 1.40 NA; photo adaptor for  high resolution digital camera Leica DFC500; 10x oculars;  Abbe condenser. 235 Lector dr. Fusu Lucian

Lector dr. Ovidiu Popovici

lucfusu@yahoo.com

tel: 0740751967

ovidiu.alin@email.ro

tel: 0740703969

15 Refractometer  Abbé Field measurement: 1.3000 la 1.7200nD; 0 la 95 % Brix 455 (b,c) dr. Marius Nicuşor Grigore mariusgrigorepsyche@yahoo.com

tel: 0766307718

16 Leica S6 stereomicroscope Optical data: 6.3:1; Zoom range 15.75x-100x; 25x oculars with 9.5 mm object field; Measurement reticule 5mm/0.5mm. 362 Lector dr. Fusu Lucian

Lector dr. Ovidiu Popovici

lucfusu@yahoo.com

tel: 0740751967

ovidiu.alin@email.ro

tel: 0740703969

17 Leica M205A stereomicroscope Optical data: 20.5:1; Zoom range 7.8x-160x; 16X oculars with 15mm object field; Planapochromatic 1.0X objective, 60mm working distance; Planapochromatic 2.0X objective, 20mm working distance; trinocular video/ phototube 100%-0% or 0%-100%. 235 Lector dr. Fusu Lucian

Lecturer dr. Ovidiu Popovici

lucfusu@yahoo.com

tel: 0740751967

ovidiu.alin@email.ro

tel: 0740703969

18 High resolution digital camera for microscopy

Leica DFC500

12Mpxl resolution, CCD 2/3” sensor, progressive scan, 6.7µm x 6.7µm pixel size, 14 Bit Analogical/Digital Convertor, FireWire connection.

LAS Multifocus Software

235 Lector dr. Fusu Lucian

Lector dr. Ovidiu Popovici

lucfusu@yahoo.com

tel: 0740751967

ovidiu.alin@email.ro

tel: 0740703969

19 Portable fluorimetru for chlorophyll Fluorimetru for chlorophyll, which is based on the principle of pulse modulated. 455 drd. Adrian Bălănici;

drd. Toma Stoleru

adrian.balanici@uaic.ro

tel: 0726210293;

tomi.stoleru@gmail.com

tel: 0743828472

FACULTY OF CHEMISTRY

LABORATORY FOR THE INVESTIGATION OF PHYSICO-CHEMICAL PROCESSES IN THE ATMOSPHERE AND THE TESTING OF NEW ENVIRONMENTAL TECHNOLOGIES FOR THE DESTRUCTION OF GASEOUS POLLUTANTS

1. TGA-DSC/DTA thermal analysis system, F3 Jupiter STA NETZSCH type, coupled with a FT-IR spectrometer, Tensor 27 BRUKER type.

Contact: Associate Professor, Ph.D., Romeo-Iulian Olariu, e-mail oromeo@uaic.ro, tel. 02320201354

Features: The system is designed to study the behaviour of ceramic, composite polymeric nanomaterials alloys samples at high temperatures. The system operates in the temperature range between 25oC and 1550oC. The adapter has a heated transfer line (thermostat up to 300°C) allowing the transfer of gases, resulting from the analysis, to a FTIR spectrometer detector type.

2. Organic Carbon/Elemental Carbon Analyzer, SUNSET LABORATORY INC.

Contact: Associate Professor, Ph.D., Cecilia Arsene, e-mail carsene@uaic.ro, tel. 02320201354

Features: OC/EC analyser is suitable for Organic Carbon and Elemental Carbon analyses from aerosols particles collected on a quartz filter from the air by using a thermo-optical method. The operating principle of the analyzer is based on optical thermal controlled desorption of samples collected on a quartz filter in an inert atmosphere followed by oxidation and detection by using a flame ionization detector – FID. OC/EC analyzer has a dual optical system that allows simultaneous operation of optical reflectance or transmittance.

3. GC-FID-MS (Turbo) – TDSG-TDSA – Gas Chromatograph with flame ionisation and mass spectrometer detectors and thermal desorption unit, Agilent 7890 GC with FID and MS Agilent ion trap 240MS with termodesorbţie Gerstel, AGILENT TECHNOLOGIES

Contact: Associate Professor, Ph.D., Cecilia Arsene, e-mail carsene@uaic.ro, tel. 02320201354

Features: Chromatograph is for analysis of polar, non-polar, semivolatile and volatile compounds and is equipped with both FID and MS detection, with autosampler and thermal desorption Gerstel unit type.

4. GCxGC – Gas Chromatograph Agilent 7890 GC with MS Agilent 5975C, AGILENT TECHNOLOGIES

Contact: Associate Professor, Ph.D., Cecilia Arsene, e-mail carsene@uaic.ro, tel. 02320201354

Features: Chromatograph is suitable for analyses of mixtures of organic compounds by using “comprehensive GCxGC” technique. Provide flexibility in operating configuration using both GC x GC separations and back flush functionality.

5. Scanning Mobility Particle Size (SMPS) unit, TSI

Contact: Associate Professor, Ph.D., Cecilia Arsene, e-mail carsene@uaic.ro, tel. 02320201354

Features: Instrument, with specialized software, is intended for classification and quantification of particles in terms of number, volume and surface (aerodynamic particle). The system consists of Particle Counter TSI 3936L87, an SMPS type-N mode classification particle size electrostatic with differential mobility analysis module type DMA 3081 with three impactors particle counter (CPC) model TSI 3787, a neutralizer TSI 3077, an air filtration equipment TSI model 3074B and an atomizer TSI model 3076. System is suitable for operating in tandem with HR-ToF-AMS spectrometer chemical analysis of aerosols Aerodyne.

6. Gas analyzers, ECOTECH

Contact: Associate Professor, Ph.D., Romeo-Iulian Olariu, e-mail oromeo@uaic.ro, tel. 02320201354

Features: The system includes a CO2 analyzer with internal pump model EC 9820, an ozone analyzer with internal pump model EC 9810, a CO analyzer with internal pump model 9830 EC, SO2 analyzer with internal pump model EC9850, a NO/NO2 analyzer model 9841 EC and an ozone generator, model 1100TS.

7. FT-IR spectrometer Vertex 70 coupled with FT-Raman Module II RAM, BRUKER

Contact: Associate Professor, Ph.D., Romeo-Iulian Olariu, e-mail oromeo@uaic.ro, tel. 02320201354

Features: FT-IR spectrometer includes all components necessary for optical and electronic spectral analyses in the range of 8000 cm-1 to 350 cm-1, 10000 cm-1 to 380 cm-1 and 680 cm-1 to 50 cm- 1. Raman module is external and can work in a spectral range between 3600 and 70 cm-1. Excitation laser source is of Nd:YAG type.

FACULTY OF PHYSICS

1. LIF system (pulsed dye laser):

Contact: Dr. Ilarion MIHAILA, Plasma physics Laboratory, Phone: 0232201188

e-mail: ilarion.mihaila@gmail.com

Features: pumping laser: NdYag Laser (fundamental wavelength 1064 nm, pulse energy 800 mJ), wavelength domain: 300-1300 nm, pulse energy: up to 100mJ (depending of the chosen wavelength), pulse width: 5-6 ns, Produced by Quantel SA, France2.

2.HPR-60 Molecular Beam Sampling Mass Spectrometer System, for Analysis of Neutrals, Neutral Radicals and Ions (produced by Hiden Analytical, UK)

Contact: Dr. Ioana Rusu, Plasma Physics Laboratory, tel. 0232 201187

iorusu@uaic.ro

Features: HPR-60 240 l/sec system, for sampling pressures to 100 mbar, HPR-60 Intermediate pumping stage for molecular beam sampling at atmospheric pressure, EQP 1000 series system, 2500 amu, with positive and negative ion detection, 0 +/- 1000eV energy option.

Atmospheric Physics Section (new gas sensors for air pollution monitoring)

ROOM 171; Contact Person: Dr. Liviu Leontie; phone 0232-201168; e-mail: lleontie@uaic.ro

 

1 Portable Gas Detector X-am 500 Dräger Portable Gas Detector

Measured concentrations: flammable gases (0−100% LEL), O2 (0−30.0%), H2S (0−100 ppm), CO (0−500 ppm), SO2 (0−20.0 ppm), NO (0−250 ppm), NO2 (0−20.0 ppm), Cl2 (0−10.0 ppm), HCN (0−100 ppm), NH3 (0−50 ppm), PH3 (0−5.0 ppm)

2 Gas chamber with control accessories System composed of Controlled Atmosphere Chambers with accessories and annexes.

1. Controlled atmosphere tube furnace with indirect heating with transport platforms for ceramic samples.

- Gas cylinders (pure air, CO2, CO, O2, Ar, NO2);

- Chemical hood.

2. Controlled atmosphere parallelipipedic furnace.

3 Automated weather station Professional Automated Weather Station, model Wheater Hawk GSM-240

Equipped with: data recorder, anemometer, wind vane, rain gauge, external sensors for temperature and air humidity, solar radiation sensor, atmospheric pressure sensor.

The station is controlled by specialized software, which records and calculates all weather data related to temperature, relative humidity, atmospheric pressure, wind (direction and speed), precipitation, soil solar radiation.

Humidity: 0-100 %RH (error de  ±5 % de la 90 la 100% RH şi  ±3 % de la 10 la 95% RH).

Temperature: -40-+50 °C (accuracy of ±0.5 °C).

Precipitations: 0-500 mm/h (resolution of 1 mm).

Atmospheric pressure: 15-115 KPa (accuracy below ±1.5%)..

Wind direction: 0-360 o  mechanically, 0-352 o electric (linearity of 1% and sensitivity of 1m/s).

Wind speed, threshold:  0.78 m/s.

Solar radiation in the range  0-2 kW/m2 (accuracy of ±2.5 %), spectral range: 300 − 1100 nm.

4 Higrometer-thermometer Temperature: -28-60 oC (accuracy: ±1 oC).

Relative humidity: 10-95 % (accuracy: ±3 %).

Calculates the dew point and wet bulb temperature.

PC connection accessories.

5 Precision Impedance Analyzer with accessories Precision Impedance Analyzer (AGILENT) with accessories

Composed of:

1. Impedance Analyzer

2. Equipment for semiconductor materials and insulation resistance measurement

1. Measuring

|Z|-θ, R-X, Ls-Rs, Ls-Q, Cs-Rs, Cs-Q, Cs-D, |Y|-θ, G-B, Lp-G,

Lp-Q, Cp-G, Cp-Q, Cp-D, Complex Z-Y, |Z|-Ls, |Z|-Cs, |Z|-Lp,

|Z|-Cp, |Z|-Rs, |Z|-Q, |Z|-D, Lp-Rp, Cp-Rp.

Frequency range: 40 Hz-110 MHz (resolution: 1 mHz).

Impedance module: 20 mΩ – 20 MΩ.

2.

Resistance measurement range: 1 KΩ – 1000 TΩ.

6 Thermal Analysis System Simultaneous Thermal Analysis System TGA-DSC/DTA for polymers, ceramics, composites, nanomaterials, metals and alloys Model STA 449 F1 Jupiter (Netzsch-Germany)

Temperature range: -150 – ~+1000°C.

TGA resolution: 0.025 µg over all sample load/measurement range, of 5 g.

DSC resolution: 0.25 µW.

Minimum heating/cooling rate: 0.001 K/min.

DSC/DTA dynamic domain: 5000 µV.

TGA-DSC-cp sensor.

7 Multimeter  High performance, 7½-digit multimeter, Six slot system, front display and front keypad, Ethernet, USB and IEEE488 interfaces

(KEITHLEY  System Switch/ Multimeter 3700 Series)

Voltage cc : 0 – 300 V (basic accuracy: 0.02%; resolution: 10 nV).

Voltage, ac: 0 – 300 V (basic accuracy: 0.05%; resolution: 100 nV).

Current, cc: 0 – 3 A (basic accuracy: 0.3 %; resolution: 1 pA).

Current, ac: 0 – 3 A (basic accuracy: 0.3 %; resolution: 1 nA).

2 wire / 4 wire resistance: 100 nΩ – 120 MΩ (resolution: 100 nΩ; basic accuracy: 0.04 %).

Frequency: 3 – 500 KHz (accuracy: 0.01 %).

Period: 2 μs – 330 ms.

Temperature:

- J, K, N, T, E, R, S, B type linearized thermocouples

- 4-wire / 3-wire RTD: PT100, D100, F100, PT385, PT3916; range: -200 −  +630 0C.

Thermistor: 2.2 kΩ, 5 kΩ and 10 kΩ; range: -80 − +150 0C.

8 Programmable Current Source Programmable cc and ac Current Source

Model KEITHLEY 6221

Current: 2 nA − 100 mA.

Resolition: 100 fA − 10 µA.

Includes Ethernet, IEEE-488, RS-232, Trigger Link and digital I/O interfaces.

9 Electrometer KEITHLEY High Performance Programmable Electrometer, Model 6517B

Resistance: 2 MΩ − 200 TΩ (resolution: 10 Ω − 1 GΩ).

Current: 20 pA − 20 mA (resolution: 100 aA − 100 nA).

Voltage: 2 −  200 V (resolution: 10 µV − 1 mV).

Charge: 2 nC − 2 µC (resolution: 10 fC − 10 pC).

Input impedance: >200TΩ in parallel to 20pF.

Accessories.

FACULTY OF GEOGRAPHY AND GEOLOGY

THE ENVIROMATICA LABORATORY

 

1.             GEOMATICS LABORATORY
Contact person:  Assoc.Prof. Daniel  CONDORACHI,  building B, floor 3, tel: 0232201489
e-mail: condordan@yahoo.com;
               Hardware equipment (workstations), GIS software – TNTMips 2011 (1 commercial license + 20 academic ones),  EXELIS ENVI 5.0 ( 1 commercial license and 25 academic ones),  SoundPLAN 7.0 – 1 commercial license.
Features: State of the art workstations useful for modeling and processing large and very large spatial information (like LIDAR and RADAR images, high resolution multispectral satellite images, etc) which request intensive computing capacity and needs a long time and have high performance video displays for data visualisation; desktop PCs for simple operations for collecting, database creation and primary processing of various data needed in GIS/RS projects.
- Dedicated software’s for creation, analysis and processing spatial data integrated in projects of Geographic Information Systems;
- for Remote Sensing (RS), photogrammetry and image interpretation which allow complex processing and analysis for multispectral satellite imagery and also for RADAR, LIDAR, etc. images by using specific algorithms for supervised and unsupervised classification and also object oriented;
- Expert software for spatial modeling of environmental noise and also for air pollutants.

2.               ENVIRONMENTAL ANALYSIS LABORATORY
Contact person:  Assoc. Prof. Iuliana-Gabriela BREABAN, building B, floor 3, tel: 0232201480; e-mail: : iulianab2001@yahoo.com;
1.              ICP-MS mass spectrometer with inductively coupled plasma G3281A, AGILENT TECHNOLOGIES - Year 2012
Features: perform trace element analysis, model Agilent 7700 Series system with hyperbolic quadrupole generating high frequency response, sensitivity for small masses abundance of 5·10

-7

  and 10

-7

for large masses, limits of detection (ng/L) without using a gas:

9

Be

59

Co

115

In

209

Bi
2.       Laser ablation system LSX 266, CETAC TECHNOLOGIES - Year 2012
Features: Equipment used by direct coupling to ICP-MS for the analysis of solid samples, geological and other environmental. Nd: YAG laser with variable aperture size 10-200 μm; DigiLaz G2 integrated laser system controlled by software, sample mapping function that allows full viewing and quick navigation sample, 9 laser ablation methods, optical resolution
3.        Microwave reaction sample preparation system - Mars 6 CEM CORPORATION, year 2012
Features: Equipment for sample preparation for ICP-MS. It has a simple magnetron isolated from reflected energy with a 1800 W deliver energy, adjustable, stainless steel enclosure fitted with automatic locking lid, exhaust system for corrosive and toxic gases, automatic overtemperature or pressure protection, a database of 100 methods of mineralization with the possibility of upgrading.
4.      Mercury Analyzer - atomic absorption spectrophotometer model Ra - 915 + LUMEX Ltd - Year 2012
Features: Portable analyzer for mercury determination based on absorption line of 254 nm with background correction by Zeeman effect to analyze the samples in gaseous, liquid and solid state; without preliminary accumulation on a gold absorber layer. Extended measurement dynamic range, limit of detection of mercury in the air in real-time operation mode is very low (2 ng/m

3

); no sample preparation requires, operating field through internal batteries, equipped with attachments RP 91 for cold vapor technique samples for liquid and RP 91C pyrolysis for solid samples. 
5.      TOC Analyzer multi N/C ® 2100 series, ANALYTIC JENA - Year 2011
Features: Analyser multi N/C

®

 2100 series determine total organic carbon, total inorganic carbon, volatile and nonvolatile organic carbon in solid and liquid samples, provided with a special module for analyzing solid samples (soil, sludge).
6.      ISO 7 clean rooms - Year 2012
Features: Providing a controlled atmosphere for ICP-MS laboratory, sample preparation room and corridor access with ISO 7 (10,000); all finishes complying with the requirements of the pharmaceutical industry, non-broadcast, non-retention; equipped with central air handling, chillers, filters, exhaust systems and air input, sensor pressure monitoring system.

FACULTY OF ECONOMICS AND BUSINESS ADMINISTRATION

THE LABORATORY OF ECONOMIC AND ENVIRONMENTAL STUDIES AND ANALYSIS

Contact Person: Associate professor, Ph.D., Costică MIHAI

e-mail: ticu@uaic.ro

Tel. 40232.201446

  1. Hardware(servers, computers), recording and presentation(video, voice) and general and specific software(SPSSProfessional10 licenses)

Characteristics of Software: SPSS IBM Statistics

The IBM SPSS Statistics Professional Edition goes beyond the core statistical capabilities offered in the Standard Edition to address issues of data quality, data complexity, and automation and forecasting.

The IBM SPSS Statistics Professional edition includes the following key capabilities:

  • Linear models.
  • Nonlinear models.
  • Simulation capabilities.
  • Customized tables.
  • Data preparation.
  • Data validity and missing values.
  • Decision trees.
  • Forecasting.